MIL-PRF-27210J
TABLE II. Test requirements
First Article
Periodic
Quality
Test
Inspection
Characteristic
Inspection
Inspection
Conformance
Method
Paragraph
Paragraph
Inspection
Purity Type I
Required
Required
Required
3.2
4.5
1
Purity Type II
Required
Required
Required
3.2
4.5
Odor
Required
Required
Required
3.3.1
4.5
Minor Constituents
Required
Required
Not Required
Table I
4.5
1
Moisture
Required
Required
Required
3.3.3
4.5
Filled Containers
(Type I)
Pressure
Required
Required
Required
3.7.1
4.4.1
Leakage
Required
Required
Required
3.7.2
4.4.2
Note 1: Reported for correlation purposes only.
4.2 First article, periodic, and quality conformance inspections.
4.2.1 First article inspection. First article inspection shall be defined as a preproduction sample.
Prior to initial delivery of Type I or Type II oxygen, a representative product specimen shall be obtained as
specified in 4.3.1.1 (Type I) or 4.3.1.2 (Type II) and forwarded to the designated laboratory (6.2). The
product shall meet the requirements in 3.2 and 3.3.
4.2.2 Periodic inspection. A representative product specimen of oxygen shall be obtained as
specified in 4.3.1.1 (Type I) or 4.3.1.2 (Type II) and shall be taken once every 60 calendar days for the
duration of the contract. This sample shall be shipped to the specified laboratory (6.2) for testing to
determine compliance with requirements specified in Table II. The specified laboratory shall also test for
purity and moisture if there is sufficient sample. The purity results for Type II oxygen and the moisture
results for Type I and Type II oxygen shall be reported for correlation purposes and shall not be used to
determine compliance to requirements of 3.2 or 3.3.3.
4.2.3 Conformance inspection. Quality conformance inspection shall consist of the following:
a. Individual container / cylinder inspection (see 4.2.3.2).
b. Sampling inspection per lot (see 4.2.3.3).
4.2.3.1 Place of inspection. Quality conformance inspection shall be performed at source.
4.2.3.1.1 Type I oxygen. Quality conformance inspection on cylinders filled with Type I oxygen
shall be performed at the site of filling (see 6.2).
4.2.3.1.2 Type II oxygen. Quality conformance inspection shall be performed on samples taken
from Type II oxygen transport container prior to leaving the site of filling. The transport container shall not
be permitted to take on further liquid oxygen between inspection at the filling point and arrival at its
destination, unless all quality conformance inspections are performed on the contents after such filling.
4.2.3.2 Individual container / cylinder inspection. Individual inspection will be as follows.
4.2.3.2.1 Type I Individual Inspection. Each cylinder filled with Type I oxygen shall be subjected
to the tests in Table III.
4.2.3.2.2 Type II individual inspection. After filling the shipping container, two product specimens
shall be drawn from each container. One specimen shall be in liquid state and subjected to the odor test
specified in 4.5. The other specimen shall be vaporized and subjected to the tests in Table III, as
specified in 4.5.
5