MIL-PRF-27210J
6.2.1 Inspection at source. DLA Energy awarded contracts will delegate Contract Quality
Assurance (CQA) to DLA Energy QARs.
6.3 Over-packing Samplers for transport should be suitably packaged in accordance with ATA
and DOT regulations to protect them during shipment. The packaging should be inspected and those
with large amounts of wear or damage should be replaced to ensure prompt shipment to and from the
laboratory.
6.4 Government laboratories. These laboratories participate in the Air Force Aviator's Breathing
Oxygen Correlation Program. Contracting officers may obtain a list of approved Government laboratories
by contacting to the AFPA/ PTPT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB OH 45433-
7632. See also Table VI.
TABLE VI. Laboratories
CALIFORNIA
JAPAN
Aerospace Fuels Laboratory
Aerospace Fuels Laboratory
(KADENA AB)
AFPA/PTPLE
AFPA/PTPLG
1747 Utah Ave, Bldg 6670
Bldg 854
Vandenberg AFB CA
Kadena Air Base, Okinawa JA
93437-5220
APO AP 96368-5162
FLORIDA
Aerospace Fuels Laboratory
OHIO
Aerospace Fuels Laboratory
AFPA/PTPLH
AFPA/PTPLA
15251 Scrub Jay Street
2430 C St, Bldg 70, Area B
Bldg 54800
WPAFB OH
Cape Canaveral AFS FL
45433-7632
32920-7519
UNITED KINGDOM
Aerospace Fuels Laboratory
(RAF MILDENHALL)
AFPA/PTPLF
Bldg 725, RAF Mildenhall UK
APO AE 09459-5025
6.5 Particulate contamination. Particulate matter may be introduced and accumulate during
transfer and storage of oxygen. Recommend that users control particulate matter by the installation of
filters in oxygen transfer lines.
6.6 Subject term (key word) listing.
Aerospace
Code, Color
Contaminant
Cryogenic
Cylinder
Filling pressure
Solvent
Spectroscopy, Infrared
Valve
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business